§ Type 03 — Application

Commercial

Scalable modular roof protection for commercial buildings, warehouses, factories, manufacturing plants and distribution centres.

Rainmaker® roof protection installed on a commercial property
§ Overview

Zoned configuration — COM

Covers commercial buildings, warehouses, factories, manufacturing plants and distribution centres — with scalable, zoned modular roof protection.

Zoned configuration for long commercial rooflines, where modules are grouped into independently valved zones so demand stays inside the site supply.

Use the Rainmaker System Designer to configure the modular platform to your architecture, water source and roofline — the calculator returns module count, layout and pricing in under two minutes.

§ Intended applications

Specified for these environments.

  • Retail centres, offices and mixed-use commercial buildings
  • Warehouses and distribution facilities
  • Long single-ridge roofs requiring staged activation
  • Exposed elevations and boundary walls carrying their own runs
  • Summer roof-temperature and cooling-load reduction
Not specified for
  • Process-hazard or flammable-liquid fire suppression duties
§ Engineering specifications

Specified for commercial conditions.

Only the data relevant to this configuration is listed. Quantities and total flow are confirmed for your property in the Preliminary Protection Design Report.

Module & zone configuration

Module length
6 m (standard part throughout)
Flexible sprinkler heads per module
2
Zoning
Independently valved zones, configured per building
Nominal flow per module
≈ 1 500 L/h
Scaling method
Add modules and zones — geometry unchanged

Mounting & installation

Mounting position
Roof ridge and/or exposed exterior walls
Bracket
UV-stabilised PVC ridge or wall bracket
Fixing method
Screw-fixed and epoxy bonded to approved surface
Manifold
Zone valves grouped at an accessible manifold
Installation route
Registered plumber / contractor

Coverage

Spray radius (per sprinkler head)
12 metres
Coverage strategy
Continuous overlap maintained within each zone
Activation
Zone-by-zone, matched to the exposed elevation
Protected surfaces
Roof envelope, parapets, wall faces, perimeter band

Water supply & flow requirements

Minimum operating pressure
2 bar at inlet, per active zone
Flow planning
Peak demand calculated on simultaneous zones only
Typical source
Municipal main, site tanks or fire reserve
Booster pump
Sized to the largest simultaneous zone group
Control
Manual zone valves at the manifold
§ Engineering notes

Why this configuration is built the way it is.

  • Zoning is the primary engineering tool: it keeps flow within the available supply instead of oversizing the connection.
  • One module part number across the building simplifies facilities stores and spares holding.
  • The site QR code at the manifold links to the current installation and operating guidance.